This sheet works a 32" deck two ways. Option A uses the fewest risers the IRC allows, 5 at 6-3/8" on 10" treads. Option B adds one riser and uses 11" treads for a gentler 5-5/16" step. Both come with hook-once tape marks for the stringer edge, below the calculator.
Option A: 5 risers at 6-3/8"
32" ÷ 7.75 = 4.13, rounded up to 5 risers, each 6-3/8"+ (6.4000", 162.6 mm). On 4 treads of 10" the stair lands 40" (3' 4") out from the deck and climbs at 32.6°; 2R + T scores 22.80".
Each step is 11-7/8" along the stringer edge. Notches cut 5-3/8" deep, leaving 5-7/8" of throat in a 2x12; the cut length is 4' 2-3/8", so buy 8 ft stock.
Option B: 6 risers at 5-5/16"
One more riser drops each step to 5-5/16"+ (5.3333"). With 11" treads the run grows to 55" (4' 7"), 15" more than Option A, and the angle eases to 25.9° with 2R + T at 21.67".
The diagonal is 12-1/4"−, the throat 6-7/16", and the stringer cut length 5' 3" (8 ft).
Cutting the bottom and the top
Take the tread thickness off the bottom riser: 6-3/8" becomes 5-3/8" under 1" 5/4 or composite treads, 4-7/8" under 1-1/2" 2x6 treads. Every finished step then measures 6-3/8".
At the top, the last tread notch sits 7-3/8" below the finished deck for 1" treads. Hung flush from the rim, the stringer edge meets the rim face 1" below the finished deck surface.
Code notes for this deck
5 risers means a handrail is required (four or more risers), 34" to 38" above the nosings.
At 32" the open sides need a guard: 34" above the nosings, no opening wider than a 4-3/8" sphere, and the tread-riser triangle under 6".
The 40" run is within the 6'-0" a cut 2x12 stringer may span under DCA 6, so no mid-support is needed.