This sheet works a 60" deck two ways. Option A uses the fewest risers the IRC allows, 8 at 7-1/2" on 10" treads. Option B adds one riser and uses 11" treads for a gentler 6-11/16" step. Both come with hook-once tape marks for the stringer edge, below the calculator.
Option A: 8 risers at 7-1/2"
60" ÷ 7.75 = 7.74, rounded up to 8 risers, each 7-1/2" (7.5000", 190.5 mm). On 7 treads of 10" the stair lands 70" (5' 10") out from the deck and climbs at 36.9°; 2R + T scores 25.00".
Each step is 12-1/2" along the stringer edge. Notches cut 6" deep, leaving 5-1/4" of throat in a 2x12; the cut length is 7' 7-3/8", so buy 8 ft stock.
Option B: 9 risers at 6-11/16"
One more riser drops each step to 6-11/16"− (6.6667"). With 11" treads the run grows to 88" (7' 4"), 18" more than Option A, and the angle eases to 31.2° with 2R + T at 24.33".
The diagonal is 12-7/8", the throat 5-9/16", and the stringer cut length 8' 9-13/16" (10 ft).
Cutting the bottom and the top
Take the tread thickness off the bottom riser: 7-1/2" becomes 6-1/2" under 1" 5/4 or composite treads, 6" under 1-1/2" 2x6 treads. Every finished step then measures 7-1/2".
At the top, the last tread notch sits 8-1/2" below the finished deck for 1" treads. Hung flush from the rim, the stringer edge meets the rim face 1" below the finished deck surface.
Code notes for this deck
8 risers means a handrail is required (four or more risers), 34" to 38" above the nosings.
At 60" the open sides need a guard: 34" above the nosings, no opening wider than a 4-3/8" sphere, and the tread-riser triangle under 6".
The 70" run is within the 6'-0" a cut 2x12 stringer may span under DCA 6, so no mid-support is needed.